COMPLIANCE
NIST CSF 2.0 for MSM manufacturing, Industrial IoT, IoT gateways and the industrial edge.
The NIST Cybersecurity Framework 2.0 organises security into six functions. NilWire translates each one into a question a plant owner can answer, and engineers the plant network, the gateways and the edge to answer it.
SIX FUNCTIONS, SIX QUESTIONS
NIST CSF 2.0 for the plant owner.
GV
Govern
Who owns plant security decisions, and where are they written down?
ID
Identify
Is every machine, sensor and gateway on one list, with its state?
PR
Protect
Is the plant network in segments and zones, with east-west traffic between zones allow-listed and the OT behind its own firewall?
DE
Detect
Would you see an unexpected connection to a machine, or one machine reaching another it has never used before?
RS
Respond
Who acts, and how, when something goes wrong?
RC
Recover
Has the plant data been restored in a real test?
IoT gateways
The boundary device between the plant and IT.
Facts travel up from the machine into IT, and only validated instructions travel back down. The gateway is where that discipline is enforced.
Hardened configuration
Default accounts removed, services reduced, firmware current.
Read-only towards machines
Machine data read without touching control logic.
Authenticated and encrypted towards IT
MQTT and OPC UA over secured links.
Every exchange logged
One controlled, logged path for plant data into IT.
On the inventory
Each gateway listed with its firmware state, from commissioning to upgrading.
INDUSTRIAL EDGE AND INDUSTRIAL IOT
Machines connected as they stand.
Protocol translation at the edge
RS-232, RS-485 and Modbus translated into MQTT and OPC UA beside each machine.
Sensors and meters
Industrial IoT for machines with no ports.
Segmented and zoned plant networks
IEC 62443 zones and conduits, built for dust, heat and distance. East-west flows between zones pass through allow-listed conduits.
Supporting standards
The references behind the design.
ISA/IEC 62443
Zones and conduits for industrial automation and control systems, with allow-listed east-west conduits.
NIST SP 800-82r3
Operational technology security, including network segmentation guidance for OT.
NIST SP 800-213 and 800-213A
IoT device cybersecurity guidance and requirements.
NIST SP 800-183
Networks of things.
HOW NILWIRE ANSWERS IT
Requirement, stack, evidence.
| REQUIREMENT | STACK | EVIDENCE |
|---|---|---|
| Identify | 07 Industrial IoT and asset lifecycle | A live record of every asset and its state |
| Protect | 01 Architecture · 06 Industrial edge | Segments and zones with allow-listed east-west flows, and one controlled OT path through the gateway |
| Detect | 04 Cybersecurity control architecture | Passive east-west monitoring inside OT and at the boundary (DE.CM-01), so lateral movement is seen early, tested |
| Recover | 04 Controls · 05 Governance | Restore test records for plant data |
| Govern | 05 Governance | Responsibilities and answers for lenders and export customers |
CONSULTING
Who we consult for, and where to start.
Manufacturers, growing businesses and any organisation without a sector regulator that wants one common standard to measure against.
Regulatory gap analysis
Your environment measured against NIST CSF 2.0, with a roadmap and owners.
Read more →
Security and backup check
The core protect and recover functions, tested in practice.
Read more →
Machine data pilot
For plants, a read-only connection to three to five machines through an industrial IoT gateway.
Read more →
RELATED
Continue reading.
Case study
A precision manufacturing MSME
Machines connected as they stand, through one controlled path.
MSM manufacturing
Read the case study →Insight
Facts Up, Intentions Down: The IoT Gateway Journey
From sensor signal to business system and back to the machine.
Article
Read the article →NilWire provides technical consulting and solution architecture. Legal interpretation of each regulation remains with the client's counsel.
Reviewed as of 6 November 2026
Consulting · first engagement
Start with the regulatory gap analysis.
Start small, prove it, then scale. A short written plan, with owners and dates, comes first.